WARNING: The connection opera-
tions must be carried out by qualifi ed per-
sonnel with an acknowledged experience in
the specifi c fi eld, in accordance with the ap-
plicable legislation in the country where the
appliance is installed.
The connection must be carried out with
due care and must comply with all applica-
ble regulatory and legal requirements.
To make the connection, connect the mains
line to the connection pipe of the appliance, fi t-
ting a shut-off tap (A) for the gas supply cut-off
when necessary.
Easily accessible fi lters must be fi tted down-
stream of the tap.
Parameters to be checked
Pressure
pH
TDS
Hardness
Langelier index (recommended) (**)
Salt and metallic ion content
Requested
Recommended (**)
(**) Values diff ering from these parameters may cause corrosion if combined with wrong use and environment.
10
HANDLING AND INSTALLATION

WATER CONNECTION

WARNING
supplied with drinking water having the
characteristics shown in the table.
200÷400 kPa (2÷4 bar)
7÷8.5
40÷150 ppm
3÷9°f (1.5÷5°d, 2.1÷6.3°e, 30÷90 ppm)
>0.5
Chlorine
<0.1 mg/l
Chlorides
<10 mg/l
Sulphates
<30 mg/l
Iron
<0.1 mg/l
Copper
<0.05 mg/l
Manganese
<0.05 mg/l
A
: The appliance must be
Value
3386350_inst_GB

Werbung