3.3 DialSet 3.0
DialSet is a re-lubrication calculation program, which easily determines the right time
setting for SKF SYSTEM 24 and SYSTEM MultiPoint automatic lubricators applications.
The DialSet program and documentation MP3501 can be found on www.mapro.skf.com.
4. Activation period
The lubricator has a time delay before the unit starts to supply lubricant. The delay varies
according to the time setting selected and the operating temperature. At normal ambient
temperatures, the lubricator starts to supply within a week and at -20 °C (-5 °F) within
two weeks. The lubricant in the bearing housing contains sufficient lubrication during this
activation period.
4.1 Influences on time setting
The dispense rate can be influenced by resistance in lubrication channels and the ambient
temperature.
If the ambient temperature is below -10 °C (+14 °F) then the dispense rate will be
approximately twice that shown on the lubricator. If the ambient temperature is above
+40 °C (+104 °F) then the emptying time is approximately half that shown on the
lubricator.
LAGD 60/125
7