Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from
using this product.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• It is not permitted to install a shutoff device (f.e. a
single-lever mixer) upstream of the built-in valve for
3 consumers!
• If the thermostat or mixer is set to maximum water
temperature, there is a risk of scalding at hydraulical
opening of the check valve. For this reason,
Hansgrohe recommends that you set up the "Safety
Function".
Special information for UK
If installing this product with a pump, please be aware
that it has to have negative head switching. This product
will not function with a positive head pump.
Fault
Valve stiff
Shower or spout dripping
Pushbutton cannot be actuated or is
without function
Pushbutton is jammed or stiff
Pushbutton does not snap in
4
English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Cause
- Select stop valve DN9 damaged
- Select stop valve DN9 damaged
- Safety guard of isolating valve has
not been removed
- Seal needs greasing
- Select Adapter incorrectly trimmed - Trim and mount Select Adapter
Assembly (see page 5)
(1 MPa = 10 bar = 147 PSI)
Do not use silicone containing acetic acid!
Dimensions (see page 12)
Flow diagram (see page 13)
Spare parts (see page 14)
+
Special accessories (see page 14)
order as an extra
Cleaning (see page 15)
Operation (see page 11)
Test certificate (see page 15)
Remedy
- Exchange Select stop valve DN9
- Exchange Select stop valve DN9
- Remove safety guard from
isolating valve
- Grease the seal
according to Fig. 7
(see page 6 + 9)
- First, fully press the pushbutton
down into the rosette; then, mount
the rosette
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min

Werbung

loading