Thank you for using this mini pool heat pump to heat your pool. It heats the water in your pool and
maintains a constant temperature when the air temperature is between 9 and 40 °C and the pool
water temperature is between 9 and 40 °C.This appliance is intended for use by competent or trained
users in shops, light industry and farms or for commercial use by laypersons.
Electrical protection
The power supply to the heat pump must preferably come from an exclusive circuit with regulating
protection components (30mA differential protection) and a magneto-thermal switch.
-The electrical installation must be carried out by a professional (electrician) in accordance with the
standards and regulations in force in the country of installation.
-The heat pump circuit must be connected to a protective earth circuit at the terminal block.
-The cables must be properly routed to avoid malfunctions. In case of damage, qualified persons must
be called in to prevent a hazard.
-The pump is intended for connection to a general power supply with earth connection.
-Cross-section of the cable; This cross-section is a guideline value and should be checked and adjusted
according to requirements and operating conditions.
-The tolerance of the permissible voltage fluctuations is +/- 10% during operation.
The connections must be dimensioned according to the power of the unit and the installation
condition.
Model
Circuit breaker
Maximum cable length
1,5 mm²
4 mm²
6 mm²
10 mm²
K-WP-2186
10A
84 m
135 m
200 m
335 m
These values are approximate, only an authorised technician can determine the values for your
installation. The power line must be equipped with an earth connection and a circuit breaker with a
current rating of 30 mA.
*This manual contains all the necessary information for the use and installation of your heat pump.
*The installer must read the manual carefully and follow the instructions for commissioning and
maintenance.
*The installer is responsible for the installation of the product and should follow all the manufacturer's
instructions and the application instructions. Improper installation contrary to the instructions will result in
the exclusion of the entire warranty.
*The manufacturer declines all responsibility for damage to persons, property and faults resulting from
installation that does not comply with the instructions in the manual. Any use not in accordance with
the original method of manufacture is considered dangerous.
*Please always drain the water in the heat pump in winter or when the ambient temperature drops
below 8℃, otherwise the titanium exchanger will be damaged by freezing, in such a case your warranty
will be lost.
*Please always disconnect the power supply when you want to open the casing to get inside the heat
pump, as there is high voltage inside.
*Please store the indicator in a dry place or close the insulation cover to protect the indicator from
moisture damage.