LASER LEVEL
ACCURACY CHECK
Check of horizontal line
Check of horizontal line is carried out by using 2 walls located opposite
each other at a distance of 5m.
1. Put the instrument as close as possible to the wall so that laser
emitters are located opposite the wall.
2. Move lever lock to unlocked position
plane.
Mark location of horizontal line on the wall as A1.
3. Turn the instument by 180° and mark location of horizontal line on
another wall as B1.
CONDTROL NEO X200
and switch on horizontal
user manual