400 V TWO PHASE WITH NEUTRAL WIRE (1-2-3 GROUP MACHINES)
The machine can be connected to power supplies with three phases and a neutral wire of 400 V. In this case, the
Black cable must be connected to one of the three phases, the Brown cable to a different phase, and the Blue or
Grey cable to the neutral wire. The Green/Yellow cable must be connected to the earth.
--///
Phase (R)
Phase (S)
Phase (T)
Neutral
110 V SINGLE PHASE WITH NEUTRAL WIRE (1-2 GROUP MACHINES)
IMPORTANT: The machines manufactured for use at electrical voltages of 110 V
have been manufactured with electrical elements specifically for that voltage.
They can thus only be installed at a voltage of 110 V, as indicated on the specific
electrical diagram for these voltages.
The machine can be connected to power supplies with a single phase of 110 V. In this case, the Black cable must be
connected to the permanent electrical installation phase, the Brown cable must be connected to the same phase
as the Black cable, and the Blue or Grey cable to the neutral wire. The Green/Yellow cable must be connected to
the earth.
--///
Neutral
Phase (R)
3-core machines
220 V - 240 V SINGLE PHASE WITH NEUTRAL WIRE (1-2-3 GROUP MACHINES)
The machine can be connected to supplies with a single phase of 220-240 V. In this case the Brown cable must be
joined to the phase in the permanent installation. The Blue or Grey cable must be connected to the neutral wire.
The Green/Yellow cable must be connected to the earth.
--///
Neutral
Phase (R)
110 V SINGLE PHASE WITH NEUTRAL WIRE (1-2 GROUP MACHINES)
IMPORTANT: The machines manufactured for use with electrical voltages of
110 V have been manufactured with electrical elements specifically for that
voltage. They can thus only be installed at a voltage of 110 V, as indicated on
the specific electrical diagram for these voltages.
The machine can be connected to power supplies with a single phase of 110 V. In this case the Brown cable
must be connected to this phase, and the Blue or Grey cable to the neutral wire. The Green/Yellow cable must be
connected to the earth.
--///
Neutral
Phase (R)
Page 92
All manuals and user guides at all-guides.com
Black Brown Blue or Grey Green/Yellow
Black
Brown Blue or Grey Green/Yellow
Brown
Blue or Grey Green/Yellow
Brown
Blue o Grey Green/Yellow
220-240V
110V
220-240V
110V