WARNING: In order for the machine to work correctly, the values of the said constants should not be altered.
IMPORTANT: ANY MACHINE MODEL WITH TWO BOILERS MUST NEVER HAVE THE
'Pressure Switch' OPTION SELECTED, AS THE MACHINE WORKS WITH A TEMPERATURE
SENSOR IN ORDER TO CONTROL THE COFFEE BOILER TEMPERATURE.
-
If 'On/Off' is selected, press the MENU button to confirm, and the display will show:
With the UP/DOWN buttons, select the unit of measurement for temperature, in Celsius (ºC) or in Fahrenheit (ºF).
Confirm by pressing OK and immediately the display will show:
Press the UP/DOWN buttons to select the desired hysteresis (the variation in degrees for the temperature in the
specific boiler).
Confirm by pressing OK key and immediately the display will show:
Press the UP/DOWN buttons to select the desired boiler temperature, and confirm the selection by pressing OK.
-
If 'PID' is selected, press the MENU button to confirm, and the display will show:
With the UP/DOWN buttons, select the unit of measurement for temperature, in Celsius (ºC) or in Fahrenheit (ºF).
Confirm by pressing OK and immediately the display will show:
Press the UP/DOWN buttons to select the desired boiler temperature, and confirm the selection by pressing OK.
The visual display will show:
Using the UP/DOWN buttons, select the value for each constant and confirm by pressing OK. (IT IS RECOMMENDED
THAT THOSE VALUES ESTABLISHED BY THE MANUFACTURER BE MAINTAINED.)
The visual display will show:
Initial regulation temperature for the algorithm for the three constants. (It could have a value of '2ºC / Up to
20ºC' or '3ºF / Up to 36ºF'). (IT IS RECOMMENDED THAT THOSE VALUES ESTABLISHED BY THE MANUFACTURER BE
MAINTAINED.)
Press the UP/DOWN buttons to select the desired temperature, and confirm by pressing OK.
INSTALLATION AND OPERATION MANUAL
All manuals and user guides at all-guides.com
Temperature
ºC / ºF
Histe. Temp.
xxxxxxx
Boiler Temperature
xxx ºC / xxxx ºF
ºC / ºF
Boiler Temperature
xxx ºC / xxxx ºF
KP KI KD
xxx xxx xxx
PID setting
IBERITAL
0.5ºC
Xxxxxxx
1ºC
2ºC
1ºF
2ºF
4ºF
Page 73

Werbung

loading

Diese Anleitung auch für:

IntenzNewExpression pro