In order to eliminate this alarm:
Press the MENU button until the following appears (even if the message 'Probe Unconnect') appears, do not stop
pressing MENU):
Press the MENU button repeatedly to go through various options until you see the following on the display:
The value shown on the display must be 'without pump'; if necessary, change the value by pressing the UP/DOWN
buttons.
Confirm by pressing OK.
Continue pressing the MENU button repeatedly until you can see on the display:
The value shown on the display must be 'Pressure Switch'; if necessary, change the value by pressing the UP/
DOWN buttons.
Confirm by pressing OK.
Press the MENU button various times until the display shows the 'OFF' message.
Press the 'I/O' or 'Non-Stop' button, based on the machine model, in order to turn on the machine.
ATTENTION: It is absolutely necessary that the values of the parameters 'MIXED TEA' and 'HEATING TYPE'
are 'without pump' and 'Pressure Switch', respectively, for machines with a display and boiler temperature
controlled by pressure switch.
D. LACK OF IMPULSES FROM THE FLOW METER
When the flow meter is not dosing correctly or the necessary impulses do not arrive for longer than 5 continuous
seconds, the used dose selection LED will flash and the display will indicate the flow meter and the group.
To eliminate this alarm, check the flow meters; this alarm signal is produced due to a bypass of the signal from the
meter cover, or due to a poor connection, or lastly due to and internal problem with the control unit.
It can also be caused by an unusually long feed time due to the water not flowing at an adequate speed during
dispensing.
E. CHANGE/REPLACE water filter
When the number of litres of water set in the TECHNICAL MENU is exceeded, the display will show:
With the number of litres of water previously selected to set off the alarm.
To eliminate this alarm, set the main switch to position 0. Press the dose buttons "2 coffees and 2 espressos" from
GROUP 1(on the left) simultaneously. Keep them pressed while we switch on the machine by setting the main
switch to position 1.
INSTALLATION AND OPERATION MANUAL
All manuals and user guides at all-guides.com
Language
xxxxxx
Mixed tea
with pump / without pump
Heating Type
xxxxxxx
Alarm
Flow meter GR x
ChangeWaterFilt.
xxxxxxx
Pressure Switch
Xxxxxxx
On/Off
PID
IBERITAL
Page 75

Werbung

loading

Diese Anleitung auch für:

IntenzNewExpression pro