The user can accept the alarm, in order to continue to see the display in the usual manner. When the machine is
turned off and on again, the error will once again be displayed, if it has not yet been corrected.
2.10.- CONTROL UNIT RESET ON MACHINES WITH DISPLAY
On models with a display, the control unit can be reset with the initial factory settings. To do this, switch off the
machine using the main switch. Once the machine is switched off, press the 1 espresso, 2 espressos and non-stop
buttons, simultaneously.
Keep them pressed and switch on the machine using the main switch. Once the machine is switched on, and
without having released the 3 buttons, keep them pressed for a few seconds, until the following message appears
on the display screen:
Switch off the machine using the main switch, and release the buttons. On switching on the machine, we will have
reset the control unit with the factory settings.
NOTE: Perform this action means losing any customization done on the machine, both in the technical menu and
the user menu. Accountants, visualizations, dosages, date / time and settings, climate control,..
WARNING: If the machine has a touchscreen, it will be necessary to re-enter the number of groups, and whether
or not the machine has an auto-frother.
If your machine does not regulate the temperature by temperature sensor, but does so through the action of a
pressure switch, the display will appear in the following error:
This situation is due to an incorrect selection on the heating menu. In order to eliminate this alarm, follow the steps
indicated in paragraph 2.9.3.1.3, section "C" (INTERRUPTED TEMPERATURE SENSOR), acting like a replacement unit
in question.
Page 88
All manuals and user guides at all-guides.com
Preset reset complete
T.ProbeUnconnect
Generic screen
Custom screen
(not available on all models)
Non-touchscreen display.
Touchscreen display.
INSTALLATION AND OPERATION MANUAL