EN
1. Technical Specifications
This appliance has a 230V magnetic valve into which e.g. a remote-controlled co2
controller can be inserted for co2 regulation.
Nominal thermal load max.:
Nozzle equipment:
The appliance can be used for the following types of gas and pressures
For use in
DE
AT, CH, DK, ES, FI, GB,
GR, IE, IT, PT, SE
NL
BE, FR
2. Important notes
The text in these instructions must be noted before the installation and initial operation
of the appliance.
•
The appliance is intended exclusively for use in greenhouses
•
The appliance must be screwed onto a secure, non-flammable, horizontal base
•
In wet rooms the appliance may only be connected to sockets that are fused with
RCCBs
•
Maximum provided fuse protection 16 amperes
•
The appliance may not be sprinkled with water under any circumstances
•
Any modification of the appliance may be hazardous
•
The gas supply must be shut off immediately in the event of a gas leak
•
The valve on the gas bottle must be closed after use
•
The gas bottle must be positioned in such a way that the gas pipe cannot come
into contact with hot parts of the appliance
•
The gas bottle should be fixed to a stable point
Natural gas
4,2 kW
Natural gas G20 Natural gas G25
20 mbar
25 mbar
1,5 mm
1,6 mm
Category
I
2E
I
2H
I
2L
I
2E+
10
Pressure [mbar]
20
25
20/25