Description of the functions
Stagnation rinse:
DIP switch 6
Serves to remove stagnant water that accumulates in the tub inlet during longer periods
of disuse.
DIP switch 6 ON = Stagnation rinse function enabled.
DIP switch 6 OFF = Stagnation rinse function disabled (default setting).
Time interval
Can be set from 3–48 h at
the interval control
(see p. 19).
3–48 h
SanTec OCEAN B7
28
Bath fitting
OCEAN B7
Automatic stagnation rinse
If the fitting has not been
used for the set period,
the device automatically
performs a stagnation rinse
operation for 10 s via the tub
inlet.
While stagnation rinse is in
progress, all three fill level
icons light up.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
10 s
ON
OFF
1 2
1 2 3 4 5 6
ON
OFF
1 2 3
1 2
3 4 5 6
ON
OFF
1 2 3 4
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
1 2 3 4 5
1
2
3 4 5 6
Safety
If the device is in standby
mode or if the cleaning stop
function has been enabled,
the stagnation rinse function
will only start 2 min after
standby mode ends or once
the cleaning stop function
has been disabled.
5 s before and after the
stagnation rinse, the three fill
level icons will flash rapidly.
3
4 5 6
4
5 6
5
6
6