Configuring the functions

J. DIP switches:
Function activation – DIP switches:
DIP switch
Function
1
2
3
4
Memory function for tub filling levels
5
Cleaning stop
6
Tub pipe stagnation rinse
1)
Program or functions already enabled ex factory.
Regulator controls:
G.
Bathtub filling control
set to safety flow arrest after
20 min
(configurable from 1–20 min).
After the configured maxi-
mum flow time has elapsed,
the water stops automatically.
Note on bathtub filling control:
The time configured at the bathtub
filling control defines the max.
filling time that can be stored on
any of the three touch-tronic icons
for filling the bathtub.
OCEAN B7
H.
Shower unit control
set to safety flow arrest after
10 min
(configurable from 10 s to
10 min).
After the configured maxi-
mum flow time has elapsed,
the water stops automatically.
1)
I.
Interval control
configured for automatic sta-
gnation rinse, default setting
48 h (setting range 3–48 h).
Set using DIP switch 6, see
page 28.
The general rule
applies to all controls:
Move counterclockwise to
decrease the setting.
Move clockwise to
increase the setting.