• Ensure that the towers are not under pressure and disconnect the dryer from the
system.
• Unscrew the bleed plug.
• Fully remove the adsorbent from the towers.
• Screw on the bleed plug.
• Unscrew the filling plug.
• Fill both towers with original adsorbent, as per table 2.1
• Screw on the filling plug.
• Carry out the start-up procedure as for the first start-up, as per point 4.2.
6.
Fault handling
6.1
Possible faults
Fault
Possible cause
There is no electrical voltage.
The air dryer
will not start.
Failure of electronic circuit board.
Failure of solenoid valve.
Purge air
Failure of electronic circuit board.
doesn't exit.
Injector / silencer blocked.
Air flows out
in very small
Injector / silencer blocked.
amounts.
Check the functioning of the sole-
noid valves.
There is no electrical voltage.
There is no
change in the
tower cycles.
Failure of electronic circuit board.
Mechanical problem in the intake
valve.
+7 (800) 777-83-75(звонок бесплатный)
www.v-p-k.ru
Solution
The voltage of the power supply line, the state of
fuses and the main switch should be inspected.
Replace the electronic circuit board.
Check for signals being output to solenoid valves.
Replace, if necessary.
Replace the electronic circuit board.
Remove injector / silencer.
Purge with compressed air. Replace, if necessary.
Remove injector / silencer. Clean away dirt / oil
/ dust.
Check for signals being output to solenoid valves.
Replace, if necessary.
The voltage of the power supply line, the state of
fuses and the main switch should be inspected.
Replace the electronic circuit board.
Remove the intake valve and check the free play
of the bypass washer.