Technical Data

Typ
Item no.:
Rofrost 1.1/4"
62200 / 062200Z
62220
Rofrost 1.1/4"
62201
Rofrost 1.1/4"
62202
Rofrost 2"
62203 / 062203Z
62206 / 062206Z
Rofrost 2"
62204
Rofrost 2"
62205
Defrosting ............................................................. Manual defrosting
Dimensions (L x W x H) ........................................ 550 x 255 x 315mm
Weight .................................................................. 24,8 kg (ROFROST 1.1/4")
Nominal current of the fuse to be superposed ....... 16 A
Protection type ..................................................... IP 20
Noise pressure level (L
Construction class N ............................................. Ambient temperature range +16 ... +32° C
3

Scope of delivery, transport and storage

Scope of delivery:
Essentially, the ROFROST TURBO pipe freezing system consists of the following components
or following accessories respectively:
Electric refrigerating system consisting of:
Refrigerating aggregate including housing, carry handle, lid, plastic insert as receptacle for
the reducing inserts, shutdown switch and power cord
2 cooling hoses with refrigerating tongs (evaporator system) and clamping screws with inte-
grated thermometer
Set of reducing inserts (special sizes upon enquiry)
1 tin of heat-conductive paste
Transport and storage:
Store the cooling hoses, refrigerating tongs and the reducing inserts in the portable housing.
Only store in installation position (i.e. upright) in a dry and dust-free environment at tempera-
tures between -10° C to 35° C.
Protect against impact and vibration.
14
Refrigerating
capacity
Power input
Q
in W at t
P in W
0
0
-30 ° C
310
325
310
266
310
266
310
325
310
266
310
266
¦ K
) ............................. < 70 dB(A) ¦ 3 dB(A)
pA
pA
ENGLISH
Current
Electrical
consumption
connection
I
in A
N
230 V±10
1,5
50 Hz ~
4,36
50 Hz ~
4,36
60 Hz ~
230 V±10
1,5
50 Hz ~
4,39
50 Hz ~
4,39
60 Hz ~
25,6 kg (ROFROST 2")
Cooling
agent /
amount
R404A /
110 V
90g
115 V
R404A /
110 V
110g
115 V