6. Specifications
MODEL
CAPACITY*
INPUT
Low Line Loss
Low Line Comeback
Voltage
Range
High Line Loss
High Line Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Phase
Output voltage
AC Voltage Regulation
Frequency Range
(Synchronized Range)
Frequency Range (Batt. Mode)
AC mode
Overload
Battery mode
Current Crest Ratio
Harmonic Distortion
Line
Battery
Transfer
Inverter
Bypass
Time
Inverter
ECO
EFFICIENCY
AC mode
Battery Mode
BATTERY
Type
Numbers
Recharge Time
Charging Current (max.)
Charging Voltage
PHYSICAL
Dimension, D X W X H
Outline
mm
Net Weight (kgs)
ENVIRONMENT
Operation Temperature
Operation Humidity
Operation Altitude**
Acoustic Noise Level
MANAGEMENT
Smart RS-232 or USB
Optional SNMP
* Derate capacity to 90% when the output voltage is adjusted to 208VAC.
**If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
***Product specifications are subject to change without further notice.
10K
10KL
10000VA / 9000W
≦ 2 % @ 100% Linear Load; ≦ 5 % @ 100% Non-linear Load
0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
> 90.5%
> 87%
Depending on
12 V / 9 Ah
applications
16
18 - 20
Depending on
9 hours
external
recover to
battery
90% capacity
capacity
1.0 A ± 10% 4.0 A ± 10% 2.0 A ± 10% 4.0 A ± 10%
592 x 250 x
592 x 250 x
826
576
96
38
0 ~ 40°C (the battery life will down when > 25°C)
Less than 60dB @
1 Meter
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
15K
15KL
15000VA / 13500W
110 VAC(Ph-N) ± 3 % at 50% Load
176 VAC(Ph-N) ± 3 % at 100% Load
Low Line Loss Voltage + 10V
300 VAC(L-N) ± 3 % at 50% Load
276 VAC(L-N) ± 3 % at 100% Load
High Line Loss Voltage - 10V
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
Three phase with Neutral
≧ 0.99 at 100% Load
Three Phase with Neutral
208/220/230/240VAC(Ph-N)
± 1%
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
100%~110%: 10min
110%~130%: 1min
>130% : 1sec
100%~110%: 30sec
110%~130%: 10sec
>130% : 1sec
3:1 max
0 ms
<10 ms
>91.5%
>88%
Depending on
12 V / 7 Ah
applications
2 x 16
18 - 20
Depending on
9 hours
external
recover to
battery
90% capacity
capacity
13.65 VDC*Battery Number ± 1%
592 x 250 x
592 x 250 x
826
576
134
40
<95 % and non-condensing
<1000m
Less than 65dB @ 1 Meter
33
20K
20KL
20000VA / 18000W
>91.5%
>88%
Depending on
12 V / 9 Ah
applications
2 x 16
18 - 20
Depending on
9 hours recover
external battery
to 90% capacity
capacity
2.0 A ± 10%
4.0 A ± 10%
592 x 250 x 826 592 x 250 x 576
146
40