Herunterladen Diese Seite drucken

Kyocera TJEP RE-BAR XP 25 Bedienungsanleitung Seite 34

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

1.1. Technical information
Technical info.
Weight:
Height:
Width:
Length:
Wraps per tie:
Workpiece
thickness:
Ties per
charge:
Battery:
Charging time:
1.1.1. Charger
Use only approved battery charger,
LI-196B1 (TJEP no. 115501).
1.2. Wire specification
Model:
TJEP WIRE XP
Diameter:
Length:
Material:
Ties per coil
2 wraps
3 wraps
1.3. Applications
ƒ Tying of re-bars used for: prefab. concrete units, floors
and walls
ƒ Tying of floor heating tubes
2. Battery
2.1. Durability of the battery.
If the battery is fully charged, but the operating time
significantly reduced, the battery is defective and must
be replaced.
If the battery temperature is low (10°C or lower) the
charging time will be prolonged.
Caution: Do not use defective batteries.
!
The RE-BAR tier will not work properly.
4.2. Re-cycling of Li-Ion batteries.
The batteries for the TJEP RE-BAR tier are Li-
!
Ion. It may be illegal to dispose of the battery
through the ordinary waste system. Your local
waste authorities can inform you how to dispose of and
recycle this type of battery correctly.
34 · www.tjep.eu
RE-BAR XP 25 RE-BAR XP 40 RE-BAR XP 58
2.2 kg
2.3 kg
2.4 kg
284 mm
284 mm
290 mm
100 mm
100 mm
100 mm
280 mm
293 mm
310 mm
2 or 3
2 or 3
2 or 3
8 - 25 mm
12 - 40 mm 30 - 58 mm
~ 2,600
~ 2,200
~ 2.200
(3 wraps)
(3 wraps)
(3 wraps)
14,4V 3,0Ah Li-ion
Full charge = 90 min
Box: 20 coils
(115152)
Box: 40 coils
(115153)
0.8 mm
Approx. 100 m
Galv.
RE-BAR XP 25 RE-BAR XP 40 RE-BAR XP 58
~ 220
~ 160
~ 110
~ 160
~ 120
~ 90
When disposing of the battery, make
sure that the protection cap is placed
correctly and taped to the battery.
3. Safety features
To increase safety when tying, the RE-BAR
tier is equipped with the following safety
features.
Trigger
Trigger lock
WARNING
Before use, make sure that the
!
devices work as intended. Other-
wise, do not use the RE-BAR tier.
3.1. Trigger lock
The RE-BAR is equipped with a trigger
lock. Lock the trigger when the RE-BAR tier
is not in use.
When the RE-BAR tier is not in use, lock
the trigger and remove the battery. When
you start tying, insert the battery and
release the trigger lock by pushing the lock
left and upwards.
3.2. Curl guide
If you pull the trigger while the curl guide is
open, the RE-BAR tier will make a warning
signal and refuse to tie. To make the tie,
release the trigger and make sure that the
curl guide is closed.
Curl guide

Werbung

loading

Verwandte Produkte für Kyocera TJEP RE-BAR XP 25

Diese Anleitung auch für:

Tjep re-bar xp 40Tjep re-bar xp 58