Problem, cause, solution

No reaction to control signal

Problem
The lock is not unlocked, even
though the unlocking control
input is activated.
Possible cause
Solution
The lock is simultane-
During operation via Hi-O Technology™ bus with
ously connected via
the IO module, detach the lock's grey connec-
Hi-O Technology™ bus.
tion cable on the functionless unlocking control
input (follow separate instructions on the
lock).
The voltage has just
Wait until the lock is ready for operation after a
been switched on on
restart (follow separate instructions on the
the lock.
lock).
The lock was discon-
Deactivate Plug & Play via DIP switch 3
nected from the
("DIP switch", page 46).
Hi-O Technology™ bus
with Plug & Play mode
activated..