Hayward K-Flo VSTD Serie Anwenderhandbuch Seite 26

Zentrifugalpumpe mit variabler geschwindigkeit

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59
4.5 Setting the Timer mode
The control panel allows you to program multiple sequences
(see section 2.3) or Timers t0 to t5, which do not need to follow a
chronological order.
Unused Timer settings will be deactivated.
Timer 't0' can be set to 00:00, 06:00 (by default), 12:00 or 18:00. It
cannot be deactivated.
You cannot adjust the speed of t0, it is set at 2400 rpm
• Identify the speed profile you would like to program.
The image opposite is shown as an example.
• Check whether the internal clock has been set correctly.
• Press and hold DISP/FUNC for 3 seconds
All 3 LEDs will blink and the screen will display
"ConF"
• Press DISP/FUNC twice and the screen will
display "t0"
• Press DISP/FUNC: the screen will display "06-00" -
this is the default value of t0
• Press the up / down buttons to set the value you
would like for t0 (00-00, 06-00, 12-00 or 18-00)
• Press DISP/FUNC: the screen will display "t1oFF"
• To activate this Timer setting (as an example),
press the 'up' button. The screen will display "t1
on"
• Press DISP/FUNC: the screen will display "00-00"
• Press the up / down buttons to set the desired
timetable (hh-mm)
• Press DISP/FUNC: the screen will display "0"
• Press the up / down buttons to display the desired
speed (600 to 3000 rpm or 0)
• To go to the next Timer setting, press DISP/FUNC:
the screen will display "t2off". In this example the
Timer setting stays deactivated
• Press DISP/FUNC to go to the next Timer setting
and repeat the steps (activation, timetable, Timer
setting and speed)
• Press RUN/STOP to exit and save
The display will show the current speed or StoP
USE ONLY HAYWARD
25
>3s
x 2
GENUINE REPLACEMENT PARTS
®
Pump
t4
time
ConF
t0
06-00
18-00
t1off
t1 on
00-00
20-00
0
2740
t2off
t3off
etc ...
/
1640
t1
t0
t5
t3
(t2)
20-15
StoP