2.3.
When the two outputs are in series, the voltage is controlled by
master output, but current adjustment to two outputs is still inde-
pendent. Therefore, attention should be paid to the position of the CC
adjustment (2) and (17). For example, knob (2) is at the position of
counterclockwise to end or current of slave output excesses current-
limiting protection point, at this time, the voltage of slave output will not
track the voltage of master. So knob (2) should be rotated clockwise to
maximum then the two output are in series.
2.4.
This unit can be output from front panel and rear panel at same time.
When use the unit as bench type, it is better for you to use the front
panel outputs, and when you use the unit as rack mount type, it is
better for you to use the rear panel outputs. Of course, you can use
both front panel outputs and rear panel outputs at same time.
The output current should be the summation of both front panel outputs
and rear panel outputs.
3.
Parallel using of the two adjustable outputs.
3.1.
Press the switch (9).
3.1.
At this time, the two output are in parallel, adjust voltage adjustment
(14) of master output, the voltage of two ways keep same, and slave
output CC indicator (1) lights on.
3.2.
When the two outputs are in parallel, the CC adjustment (2) of slave
output does not work. When used as CC supply, simply adjust the CC
adjustment (17) of master output, at this time, output current of both
master and slave output are controlled by it and are same, output
current is up to double
3.3.
While the two outputs in parallel, since the unit has relay switch control,
the two positive terminals and the two negative terminals of master,
slave output and shorted reliably and separately by the relay inside the
unit. You can connect the load directly between terminal (18) and (20),
(21) and (23), (18) and (23). For output current balance, connecting the
load between terminal (18) and (23) is recommended.
The LED displays are in three digits.
(20 A) of independent's maximum current.