1- Move the motor to the UP end limit by using the keys UP or DOWN.
2- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run automatically
in the DOWN direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to confirm the adjustment. The motor will run for 0,5 second in one direction, then in the
other direction. Go to stage §5.
C
1
1- Move the motor to the DOWN end limit by using the keys UP or DOWN.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automatically
in the UP direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to confirm the adjustment. The motor will run for 0,5 second in one direction, then in the
other direction. Go to stage §5.
D
1
1- Move the motor to the DOWN end limit by using the keys DOWN or UP.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automatically
in the UP direction.
3- When the motor reaches the UP End limit, press the key STOP.
4- If necessary adjust the position with the keys UP or DOWN.
5- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run automatically
in the DOWN direction.
6- Press 2 seconds the STOP key to confirm the adjustment. The motor will stop, and will run for 0,5 second in one direc-
tion, then in the other direction. Go to §5.
If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the opération 4.1* with a new transmitter and then go to step §5.
* In this case, the motor will run for 0,5 second in both directions, that means the limits setting is already done.
5
Programming the first individual control point
This operation can only be performed from the transmitter that was used for operation 4.1.
- Press the transmitter PROG Key for approximately one second.
The motor will run for 0,5 second in one direction and then in the
other. Your transmitter is now programmed to control the EHz
motor in stable mode.