Spezifikationen
system flushdns
system uptime
system name show
system version show
system display {disp_num} default extsensor
{port_num} {sen_type} set {sen_field}
system display {disp_num} default linesensor
{line_num} set {sen_field}
system display {disp_num} default portsensor
{port_num} set {sen_field}
system display {disp_num} default set
{BLANK=0,LOCAL_TIME=1,UTC_TIME=2}
system display {disp_num} default show
system display default hash set "{data}"
system display default hash show
system sensor {VSYS=0|VAUX=1|VMAIN=2|
TCPU=3} show
system {SWITCH_PORT=0} events set {OFF=0|
ON=1}
system {SWITCH_PORT=0} events show
system {SWITCH_PORT=0} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5,EVT_DISPLAY=6,EVT_CONSOLE=7,EVT_M
QTT=8}"
system {SWITCH_PORT=0} events type show
system {SWITCH_PORT=0} events mqtt retain
set {OFF=0|ON=1}
system {SWITCH_PORT=0} events mqtt retain
show
system panel enabled set {OFF=0|ON=1}
system panel enabled show
system panel port all set {OFF=0|ON=1}
system panel port all show
timer
timer enabled set {OFF=0|ON=1}
timer enabled show
timer syslog facility set {0..23}
timer syslog facility show
timer syslog verbose set {0..7}
timer syslog verbose show
timer {rule_num} enabled set {OFF=0|ON=1}
timer {rule_num} enabled show
timer {rule_num} name set "{name}"
timer {rule_num} name show
timer {rule_num} {FROM=0|UNTIL=1} set "{yyyy-
mm-dd}"
timer {rule_num} {FROM=0|UNTIL=1} show
timer {rule_num} trigger jitter set {0..65535}
timer {rule_num} trigger jitter show
timer {rule_num} trigger random set {0..100}
timer {rule_num} trigger random show
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} set "{time_date_list}"
timer {rule_num} trigger {HOUR=0|MIN=1|SEC=2|
DAY=3|MON=4|DOW=5} show
timer {rule_num} action mode set {SWITCH=1|
CLI=2}
timer {rule_num} action mode show
timer {rule_num} action {SWITCH1=0|
SWITCH2=1} {OFF=0|ON=1} set "{port_list}"
timer {rule_num} action {SWITCH1=0|
SWITCH2=1} {OFF=0|ON=1} show
timer {rule_num} action delay set {0..65535}
timer {rule_num} action delay show
timer {rule_num} action console set "{cmd}"
timer {rule_num} action console show
timer {rule_num} action hash set "{data}"
timer {rule_num} action hash show
timer {rule_num} delete
timer delete all
vt100
vt100 echo set {OFF=0|ON=1}
vt100 echo show
Expert Power Control 8031/8035
flush DNS cache
number of seconds the device is running
shows device name
shows actual firmware version
shows external sensor
shows energy line sensor
shows energy port sensor
shows other contents
shows default setting for display
sets hashed display setting
shows hashed display setting
shows internal sensors if model supports it
enable global events
shows if global events enabled
enables different event types
shows what event types are enabled
sets mqtt retain
shows if mqtt retain set
blocks panel buttons when not enabled
shows if panel buttons are enabled
enable siwtch all relays from panel buttons
shows if siwtch all relays from panel buttons
enabled
enters cmd group "timer"
enables timer functions
shows if timer a enabled
sets facility level for timer syslog
shows facility level for timer syslog
sets verbose level for timer syslog
shows verbose level for timer syslog
enables rule
shows if rule is enabled
sets name of rule
shows name of rule
sets date range of rule
shows date range of rule
sets jitter for rule
show jitter of rule
sets probability for rule
shows rule probability
sets time date list
shows time date list
sets switch or cli cmd
shows if switch or cli cmd
sets port list for switch cmd
shows port list for switch cmd
delay between cmds
shows delay between cmds
sets cmd string
shows cmd string
sets action binary form
shows action binary form
delete one timer
delete all timer
enters cmd group "vt100"
sets console echo state
shows console echo state
88