Nozzles
To prevent the nozzles from being clogged or if the nozzles are clogged, remove and clean
each nozzle. Use caution when removing the nozzles as they may break.
Upper nozzle
Lower nozzle
DW4000RM(A5)_IB_DD81-02709D-05_EN.indd 53
1. Open the door, and then pull out the
upper rack to reveal the upper nozzle.
2. Loosen and remove the nut, and then
remove the nozzle.
3. Unclog and clean the nozzle.
4. Reinsert the nozzle, and then tighten the
nut by hand.
5. Rotate the nozzle by hand to make sure
the nozzle is engaged correctly.
1. Open the door, and then pull out the
lower rack. The lower nozzle is visible
on the bottom.
2. Unclog and clean the nozzle.
3. Reinsert the nozzle.
4. Rotate the nozzle by hand to make sure
the nozzle is engaged correctly.