Herunterladen Diese Seite drucken

Collomix TMX 1000 Originalbetriebsanleitung Seite 22

Vorschau ausblenden Andere Handbücher für TMX 1000:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
TMX 1000
TMX 1500
Troubleshooting
Malfunction
Machine does not start
Machine switches off
after a short time , cannot
be switched on again
Machine does not start
up when filled, remains at
a standstill
* Work on live components may only be carried out by a qualified electrician!
Care and maintenance
The mixer must always be disconnected from the power supply by pulling the mains plug prior
to any maintenance and cleaning work.
Always ensure ease of movement for all moving parts.
The mixer is largely maintenance-free. The drive shaft is supported by ball bearings with perma-
nent lubrication.
Clean the machine immediately after use. Do not let material deposits dry.
Remove the mixing tool from the hexagon shaft and clean it outside of the mixer.
Do not tap the mixing tool and mixing tub using a hammer. Bent mixing tools can lead to damage
to the device and poor mixing results.
Replace damaged, bent or worn machine parts.
Treat moving parts, such as the bottom segment slidegate, extendable discharge chute and hex-
agons shaft from time to time with spray oil.
22
Cause
• Supply cable too long and/or cable
cross-section too small
• Plug not inserted
• No mains voltage present
• Capacitor defective
• Thermal overload protection trigge-
red (overload of the machine) -
- only for TMX 1500
• Supply cable too long and/or cable
cross-section too small
• Cable was pulled from the mains
plug
• Voltage drop in the power supply
• Capacitor defective
• Mixing quantity too high
• Mixed material too stiff
Remedy
• Check cable cross-section, must be 1.5 mm
shorten supply cable
• Insert plug
• Check mains voltage
• Replace starting capacitor*
• Let machine cool down (at least 2 min), reduce
mix as needed
• Check cable cross-section, must be 1.5 mm
shorten supply cable, <25 meter
• Insert cable again
• Check mains voltage
• Replace starting capacitor*
• Reduce the material volume
Collomix GmbH
85080 Gaimersheim
,
2
,
2

Werbung

loading

Diese Anleitung auch für:

Tmx 1500