Herunterladen Diese Seite drucken

Oase ProMax ClearDrain 7000 Inbetriebnahme Seite 14

Vorschau ausblenden Andere Handbücher für ProMax ClearDrain 7000:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Manual mode ProMax ClearDrain 7000
 C
The pump remains permanently switched on if the float switch is set vertically and the cable
points downward.
NOTE
The pump can run dry in manual mode. Running the pump dry increases wear.
Switch off the pump when the minimum water level is reached.
• Move the handle into the horizontal position and push the cable directly at the transition to
the float switch into the cable clip such that the float switch is in a vertical position.
Automatic mode ProMax ClearDrain 11000, 14000
 D
The pump switches on when the rising water reaches the sensor.
Metal contacts at the bottom of the sensor strip detect the minimum water level (switch-off
point). When the minimum water level is reached, the pump switches off.
• Fit the sensor onto the sensor strip in the desired switch-on position.
Manual mode ProMax ClearDrain 11000, 14000
 E
The pump is switched on when the sensor is inserted in the top-most position of the sensor
strip.
Metal contacts at the bottom of the sensor strip detect the minimum water level (deactivation
point). When the minimum water level is reached, the pump switches off with a brief delay.
• Repeat the process: Reinsert the sensor in the top position of the sensor strip.
Setting the residual water level
 F
The pump can pump the water down to a depth of 6 mm to 8 mm or down to 1 mm.
• Residual water level 6 ... 8 mm: Fit the spacer ring and secure with the retaining ring (bayonet
closure).
• Residual water level down to 1 mm (shallow extraction): Release the retaining ring (bayonet
closure) and remove the spacer ring.
Shallow extraction is only possible in manual mode.
14

Werbung

loading