4. Installation site requirements
Follow these instructions in order to prevent any problem with the LEX Smart Water
Softener.
Install the water softener in a dry room, which is not liable to frost. The ambient temperature
should not exceed 30 °C.
The system requires a power supply (230 V, 50 Hz) under constant voltage.
A gravity fl ow connection to the sewer for the waste water hose and the salt tank's safety
overfl ow is also necessary.
The water softening system is usually installed downstream of the protecting fi lter, the
pressure reducing valve (compulsory when the static pressure is equal to or exceeds 5.0 bar)
and upstream of a dosing pump (optional).
To prevent huge damage on the installation site due to a leaking device or supply line (for
instance in an offi ce, medical practice etc.), it has to be ensured that during the personnel's
absence the water and power supply are interrupted upstream of the system.
We recommend our leakage detector Safe-T Connect with an integrated fl oor sensor
(serial number: 2421.00.010).
Do not disconnect during the regeneration process.
When restarting the device after a service interruption, repeat the same steps as for the initial
start-up (cf. the relevant instructions for installation and start-up).
The water to be softened has to be clear, free of solid impurities as well as iron and manganese-
free.
An additional water analysis may be helpful: we will be glad to offer you support by analyzing
your water sample free of charge. Send us your sample with our accompanying letter that you
can download in the Internet under www.syr.de
Contact us for further details.
Bedienung und Wartung LEX Smart Wasserenthärtungsanlagen
> Service > Forms.