7. Maintenance / Intervals
7.1
Maintenance / Intervals
Remove the cover to service the device.
Prior to maintenance works, unplug and depressurize the device.
Set the bypass and blending valve to the bypass position.
1
Sealing kit
To ensure troublefree and durable functionality
of the system, we recommend the seal kit
1500.01.904 and the chlorinator cell 1500.00.970,
if available.
The spare parts included in the maintenance set
should be replaced approximately every other year.
Bedienung und Wartung LEX Smart Wasserenthärtungsanlagen
Maintenance
Check hardness setting
Exchange seal kit
Cleaning salt tank
Cleaning chlorinator cell *
Exchange chlorinator cell *
Functional test
* if available
Interval
quarterly
Operator
every two years
Installer
once per year
Installer
once per year
Installer
every two years
Installer
once per year
Installer