ELECTRICAL CONNECTION
The mains voltage must correspond to the voltage indicated on the rating plate
located inside the hood. If equipped with a plug, connect the hood to a wall socket
that complies with current standards located in an area that can be accessed
even after installation. If it does not feature a plug (direct connection to the mains)
or the plug is not located in an accessible area, even after installation, apply a
standard double pole switch that ensures complete disconnection from the mains
in category III overvoltage conditions, in accordance with the installation rules.
● Please note! Before reconnecting the circuit to the mains power supply, make
sure that it is working correctly, always check that the power cable is correctly
installed.
Do not use extension cords, power strips or adapters.
Mains voltage and frequency
Refer to the value indicated on the rating plate inside the hood.
Wire connection
: yellow/green
N: blue
L: brown
Replacing the power cable
The hood features a special power cable; if the cable is damaged, contact the
Service Centre for a replacement.
AIR OUTLET
(for suction versions)
Connect the hood to wall-mounted exhaust pipes and holes with a diameter equivalent to the air outlet (connecting flange).
The use of pipes and outlet holes in the wall with a smaller diameter will reduce the extraction performance and drastically
increase the noise level.
All responsibility in this regard is therefore denied.
! Use a ducting pipe with the shortest length necessary.
! Use a ducting pipe with the least number of bends possible (maximum bend angle: 90°).
! Avoid drastic changes in the ducting pipe diameter.
! The company shall not be held responsible if these regulations are not complied with.
FILTRATION OR SUCTION?
! Your hood is read to be used in the suction version.
To use the hood in the filtration version, the special ACCESSORY KIT must be installed.
Check, on the first pages of this manual, whether the ACCESSORY KIT is already supplied or needs to be purchased
separately.
Note: If supplied, in some cases, the additional activated carbon filtering system may already be installed on the hood.
Information on how to convert the hood from the suction version to the filtration version is already contained in this manual.
Extraction version
Vapours are evacuated outside through an exhaust pipe attached to the connecting flange.
ATTENTION
The evacuation pipe is not supplied and must be purchased.
The diameter of the exhaust pipe must be equivalent to the diameter of the connecting ring.
If the hood features one or more carbon filters, they must be removed.
Filtration version
The suctioned air will be degreased and deodorised before it is sent back into the room. To use the hood in this version, it is
necessary to install an additional activated carbon filter system.
12