Automatic operating mode setting (only in operating mode)
In this mode the appliance automatically selects the desired mode according to the set/ambient room temperature.
1. Press the +/- buttons(9i/10l) to select the desired temperature from 10 to 49 °C. The ST icon is active during setting
(H).
2. The selected option is automatically saved after 5 seconds. The ST icon (H) goes out, the RT icon lights up (G)
3. Press the Mode button to deactivate (2b) and select the desired mode (min/max/fan)
Note: If the temperature drops 2 degrees below the set temperature, the heater switches to warm airflow (1000 W).
If the temperature drops 4 degrees below the set temperature, the heater switches to hot airflow (2000 W). If the
temperature rises 1 or more degrees above the set temperature, the heater switches to cold airflow.
Day timer setting (only in operating mode)
1. Press the 24H button (5e) and by repeated pressings of the button set the desired shut down time (1 – 24 hours).
2. The day timer is active if the clock icon is lit on the display (P).
3. To deactivate the timer, press the 24H button again (5e) until the time 00 appears on the display, the clock icon (P)
is inactive.
Open window function setting (only in operating mode)
This function stops the operation of the appliance if the ambient temperature drops by at least 3 °C within 1 minute.
1. Press the AUTO button to activate it (3c). The open window icon (P) will appear on the display.
2. Press the AUTO button to deactivate it (3c). The open window icon (P) goes out.
Child lock setting (only in operating mode)
1. Press the Lock button to activate it (6f). Only one icon is lit on the display (A).
2. In this mode, only the ON/OFF (1a) and Lock (6f) buttons work.
3. Press the Lock button to deactivate it (6f).
60
Table of local electric heater data
Model identification no.: QH4100 BPT-2000B 5406L-Wifi
Parameter
Symbol
Value
Unit
Rated heat output
Temperature entering methods, only for electric storage heaters (select
one)
Rated heat
Pnom
2.0
kW
Manual regulation of accumulated heat with integrated
output
thermostat
Minimum
Pmin
1.0
kW
Manual regulation of accumulated heat according to room
heating capacity
temperature and / or outdoor temperature
(indicated)
Maximum
Pmax
2.0
kW
Electronic regulation of accumulated heat according to
continuous
room temperature and / or outdoor temperature
heating power
Additional electricity consumption
Heat output with fan
At rated heating
elmax
0
kW
Type of heat output / room temperature control (select one)
output
With minimum
elmin
0
kW
Single mode heat output without room temperature
heat output
control
In standby mode
elSB
0.001
kW
Two or more modes set manually, without room
temperature control
With room temperature control by mechanical thermostat
With electronic room temperature control
Electronic temperature room control with daily timer
Electronic temperature room control with weekly timer
More control options (multiple choices)
Room temperature control with person presence detection
Room temperature control with open window detection
With remote control
With adaptive on/off mode
With reduced operating hours
With infrared sensor
Contact:
Jindrich Valenta – Concept
Vysokomytska 1800
565 01 Chocen, CZECH REPUBLIC
Note:
The measured seasonal energy efficiency of heating of local electric heaters shall not be lower than the declared
value at the nominal heating capacity of the unit.
Seasonal energy efficiency of all local heaters except commercial, ηs (%)
EN
P
Parameter
Unit
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[yes]
[no]
[yes]
[yes]
[no]
[no]
[no]
38
61