BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
11
Accessories (continued)
BTL6-A-3801-2
37.6
28
Ø 4.2
16
Fig. 11-7: Installation dimensions of BTL6-A-3801-2 magnet
Weight:
Approx. 25 g
Housing:
Plastic
BTL5-P-4500-1
45
25
Ø 4.2
Fig. 11-8: Installation dimensions of BTL5-P-4500-1 magnet
Weight:
Approx. 90 g
Housing:
Plastic
Operating
temperature:
−40°C...+60°C
Special advantage of the BTL5-P-4500-1 magnet: Several
magnets on the same transducer can be separately
switched on and off electrically (actuation with a PLC
signal).
www.balluff.com
21
28
15
M5x8
11.4
Connector
For information on pin assignment, see
Table 4-2 on page 10.
BKS-S115-PU-_ _
Straight connector, molded-on cable, preassembled
M12, 8-pin
Various cable lengths can be ordered, e.g.
BKS-S115-PU-05: Cable length 5 m
43
Fig. 11-9:
Connector type BKS-S115-PU-_ _
BKS-S116-PU-_ _
Angled connector, molded-on cable, preassembled
M12, 8-pin
Various cable lengths can be ordered, e.g.
BKS-S116-PU-05: Cable length 5 m
M12x1
Fig. 11-10:
Connector type BKS-S116-PU-_ _
Fig. 11-11: Connector type BKS-S116-PU-_ _, outlet
11.5
Adjusting box
BTL7-A-CB02-S115
Scope of delivery:
Adjusting box
2 adapter cables, each approx. 0.3 m