BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
3
Construction and function
Output signal rising:
Error signal
100 %
0 %
Null point
1)
13
73
~80
~250
Mounting clamps with insulating bushes
and ISO 4762 M5x25 cylinder-head screws,
max. tightening torque 2 Nm
Fig. 3-1:
BTL6... transducer, construction
3.1
Construction
Electrical connection: The electrical connection is made
via a connector (see ordering code on page 20).
Housing: Aluminum housing containing the waveguide
and processing electronics.
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see accessories on page 18).
Nominal length: To optimally adapt the transducer to the
application, the following nominal lengths are available:
Nominal length
50...4572 mm
3.2
Function
The BTL6 transducer contains the waveguide which is
protected by an aluminum housing. A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
The magnet defines the position to be measured on the
waveguide.
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic speed.
www.balluff.com
End point
Nominal length =
Measuring range
2)
~250
Grading
5 mm
1) Unusable area
2) Not included in scope
1)
73
~80
15
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is conver-
ted by a coil into an electrical signal. The travel time of the
wave is used to calculate the position. Depending on the
version, this information is made available as a voltage or
current output with a rising gradient.
3.3
LED display
In normal operation the LED indicates the
operating states of the transducer.
LED
Operating state
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
of delivery
2)
BTL5-P-3800-2 magnet
34.8
50
LED
68
english
7