Herunterladen Diese Seite drucken

Balluff BTL6-A/C/E/G500-M PF-S115 Betriebsanleitung Seite 39

Vorschau ausblenden Andere Handbücher für BTL6-A/C/E/G500-M PF-S115:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
10
Technical data
10.1
Accuracy
The specifications are typical values for BTL6-A/C/E/G... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-2814-1S or BTL5-T-2814-1S
magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
BTL6-A/G...
BTL6-C/E...
Repeat accuracy
Sampling rate
(dependent on the nominal length)
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
1)
Max. detectable speed
10.2
Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Shock rating
Continuous shock
per EN 60068-2-27
3)
Vibration
per EN 60068-2-6
3)
Degree of protection per
IEC 60529
(when attached)
www.balluff.com
350 µV
≥ 5 µm
700 nA
≥ 5 µm
≤ ±0.002 % FS
≥ ±5 µm
Max. 2 kHz
±200 µm
±0.04 % FS
≤ 30 ppm/K
10 m/s
2)
−25°C...+70°C
−40°C...+100°C
< 90%, non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10...2000 Hz
IP67
10.3
Supply voltage (external)
Voltage, stabilized
4)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
5)
Overvoltage protection
Dielectric strength
(GND to housing)
10.4
Output
BTL6-A... Output voltage
Load current
BTL6-C... Output current
Load resistance
BTL6-E... Output current
Load resistance
BTL6-G... Output voltage
Load current
Short circuit resistance
10.5
Input
Programming inputs La/Lb
Overvoltage protection
10.6
Dimensions, weights
Housing height
Nominal length
Weight (depends on length)
Housing material
Nominal length 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
2)
level.
Individual specifications as per Balluff factory standard, resonances
3)
excluded
For
: The transducer must be externally connected via a limited-
4)
energy circuit as defined in UL 61010-1, a low-power source
as defined in UL 60950-1, or a class 2 power supply as defined
in UL 1310 or UL 1585.
A prerequisite is that no current can flow between GND and 0 V in the
5)
event of polarity reversal.
10...30 V DC
≤ 0.5 V
PP
≤ 150 mA
≤ 3 A/0.5 ms
Up to 36 V
Up to 36 V
500 V DC
0...10 V
Max. 5 mA
0.1...20 mA
≤ 500 ohms
4...20 mA
≤ 500 ohms
−10...10 V
Max. 5 mA
Signal cable to 36 V
Signal cable to GND
10...30 V DC
High-active
Up to 36 V
20.8 mm
50...4572 mm
Approx. 1 kg/m
Aluminum
english
17