opening and allow the water to drain using the pump. Please keep the drainage hose straight
(see Fig. 6).
The water tank must be drained when "P1" is indicated on the display. Please switch the unit off
o
and remove the plug on the lower drainage opening (see Fig. 7). Allow the water to drain via
the opening. The indication of "P1" will disappear after the restart of the unit.
After draining, the plugs must be secured again correctly. Please perform a drainage when the
o
unit will not be used for a prolonged period of time.
Upper
drainage
opening
Automatic recovery:
In the event of an interruption of the unit's power supply, after reactivation of the unit, it will
o
restart with the last used settings. The compressor will restart after 4 minutes. To set, please
press the sleep button 10 times within 5 seconds, the unit will emit a sound 4 times. To cancel,
repeat the previous step, the unit will emit a sound 2 times.
Cleaning
Always disconnect the appliance from the power outlet and let it cool for min. 5 minutes before cleaning.
Never immerse the appliance in water to prevent electric shocks.
Please use a soft cloth moistened with lukewarm water (below 40°C) to clean the outer surfaces and a
dry cloth to dry them off.
Do not use petrol or other chemical cleaning agents to clean the appliance.
Please remove the upper and lower dust filters for cleaning. You can use a vacuum cleaner for light
cleaning. For heavy soiling, please clean the filters with neutral detergent and lukewarm water. Please
allow the filters to air dry completely before reinserting them into the unit.
Troubleshooting
Problem
1. Unit does not start
when pressing
"POWER".
2. It's not cool
enough.
3. Unit is too loud.
4. „P1" Code
Spare parts and accessories supply (fast convenient supply)
Pump drainage opening
Fig. 5
Possible causes
The last operation was less than four
minutes ago.
Room temperature is lower than the set
temperature during operation mode
cooling.
Doors or windows are not closed.
There are heat sources in the room.
Exhaust hose is not installed or blocked.
Set temperature is too high.
Air inlet is blocked.
The ground is not even and flat enough
Water tank is full.
Fig. 6
Suggestions
Please wait four minutes.
Reset the temperature.
Close all doors and windows.
Remove the heat sources if possible.
Install the exhaust hose and make sure
that the hose is clean and not blocked by
any objects.
Reset the temperature.
Clean the air inlet
Place the unit on an even and flat surface.
Please empty the water tank.