Grohe EUROSMART COSMOPOLITAN E 36 327 Montageanleitung Seite 7

Vorschau ausblenden Andere Handbücher für EUROSMART COSMOPOLITAN E 36 327:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (open water
heaters) is not possible.
Safety notes
• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 0.3 MPa flow pressure:
• Hot water supply temperature:
Recommended (energy economy):
Fitting with battery:
• Voltage supply:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 11 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
• Water connection
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system, see the programme table on page 6.
Special accessories
Further settings and special functions are available via the
infrared remote control (prod. no. 36 407).
0.05 MPa
0.1 - 0.5 MPa
max. 1 MPa
1.6 MPa
approx. 6 l/min
max. 70 °C
60 °C
6V lithium battery type CR-P2
60 s
1 s
13cm
IP 59K
cold - right
hot - left
A
2
2500 V
100 °C
activatable
readable
activatable
deactivated
3.5 min
Approval and conformity
This product conforms to the requirements of the
relevant EU directives.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Fitting
Refer to the dimensional drawings on fold-out page I Fig. [1].
Fasten fitting to wash basin, see Figs. [2].
Connection, see Fig. [3] and [4].
Connecting the voltage supply, see Fig. [5] and [6].
Open hot and cold water supply and check that
connections are watertight.
Setting temperature limiter
1. Remove screw (A) and detach lever (B), see Fig. [7].
2. Remove screw (C) and remove temperature limiter (D).
3. Remove feather key from temperature limiter and reinsert in
the desired position. The grooves in the temperature limiter
correspond to the temperatures that can be selected, see
Fig. [8].
Assemble in reverse order.
Operation
The infrared electronics emit invisible, pulsed light.
The sensor system is adjusted so that water flow is initiated
when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s.
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s of continuous detection of an object, the infrared
electronics automatically stop the water flow.
Activating cleaning mode
• Only possible when temporary shutoff is activated
1. Hold finger against the lower area of the sensor system,
see Fig. [9].
Indicator lamp signals:
█████████████████████ ██ ██ ██ ██ ██
2.
Remove finger from the sensor system while
is displayed.
Cleaning mode is active for 3 minutes. The indicator lamp
flashes during this time.
Terminating cleaning mode prematurely
1. Hold finger against the lower area of the sensor system,
see Fig. [9].
Indicator lamp signals:
█████████████████████____
██ ██ ██
4