BWT Bewades P-Serie Einbau- Und Bedienungsanleitung Seite 21

Uv-desinfektionsanlage

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

A
B
8 8 8 8 8
Quartz glass tube
C
D
11
11
11
11
11
7 7 7 7 7
6 6 6 6 6
10
10
10
10
10
5 5 5 5 5
9 9 9 9 9
O-ring
Cleaning the glass pane of the UVC sensor unit
Cleaning the glass pane of the UVC sensor unit
Cleaning the glass pane of the UVC sensor unit
Cleaning the glass pane of the UVC sensor unit
Cleaning the glass pane of the UVC sensor unit
The UVC sensor unit consist of the following components:
-
Welded nipple with O-ring (A A A A A )
-
Measuring window (B B B B B )
-
UVC-Sensor (C C C C C )
-
Coupling ring (D D D D D )
Close the shut-off valves. Drain the unit.
Remove the sensor cable and unscrew the coupling ring (D D D D D ). Remove
the UVC sensor from the measuring window, check the glass surface of
the sensor for soiling and, if necessary, clean with an appropriate clean-
ing agent (e.g. alcohol or a mild acid such as citric acid) and a soft
cloth.
Unscrew the UV sensor (B B B B B ) from the welded nipple (A A A A A ). Clean the glass
pane with an appropriate cleaning agent (e.g. alcohol or a mild acid
such as citric acid) and a soft cloth.
Reverse the procedure to assemble the unit. When reassembling, make
sure that the o-ring sits properly in the welded nipple. Ensure that no
dirt or water enter the measuring window.
Open the shut-off valves up- and downstream of the unit.
The unit is now ready for use.
Changing the emitter
Changing the emitter
Changing the emitter
Changing the emitter
Changing the emitter
The expected service life of our UV emitters is 10,000-14,000 operating
hours. When the total emitter activations and operating hours passes
10,000, the "h" in the running time meter flashes to alert you to the fact
that the emitter has to be changed. Replace the emitter after 14,000
operating hours at the latest. Replace all emitters at the same time if
the unit has more than one emitter.
Remove mains plug.
Close the shut-off valves.
Loosen the 2 screws of the blue protective cap (11
Remove the protective cap and pull the plug (10
Remove the UVC emitter (9 9 9 9 9 ).
Insert and connect a new emitter. Ensure that the plugs (10
serted properly.
Attach the blue protective cap (11
11) and secure it with the screws.
11
11
11
W W W W W ar ar ar ar arning:
ning:
ning:
ning: F F F F For saf
ning:
or safety reasons
or saf
or saf
or saf
ety reasons
ety reasons
ety reasons, the UV emitters ma
ety reasons
, the UV emitters may only be star
, the UV emitters ma
, the UV emitters ma
, the UV emitters ma
in the unit when the blue protective cap (11) is mounted.
in the unit when the blue protective cap (11) is mounted.
in the unit when the blue protective cap (11) is mounted.
in the unit when the blue protective cap (11) is mounted.
in the unit when the blue protective cap (11) is mounted.
Open the shut-off valves up- and downstream of the unit.
W W W W W ar ar ar ar arning:
ning:
ning:
ning:
ning: The running time meter on the UV-Control II controller must
be reset when the emitters are changed (see UV-Control II installation
and operating instructions).
The unit is now ready for use.