The electrical triggering has priority over the mechanical
triggering.
I-1
3
4
5
2
1
3
4
5
2
1
I-2
Assignment of the
data bits
Operation
Check the safe functioning of the unit. Display by LEDs:
• LED green: supply voltage via the AS-i system
• LEDs yellow: external voltage supply
For trouble-free operation sufficiently treated air must be used (filtered
air 5µm, lubricated (ISO-VG10)1) or not lubricated). Once the AirBox
has been operated with lubricated air, it always has to be operated
with lubricated air as the oil removes the initial lubrication.
1)You can find further notes on compressed air and EMC/ESD for the
AirBox at www.ifm-electronic.com. Enter the article number of your
AirBox on the start page under "Data sheet direct". You receive the
additional product information by clicking on "Additional data".
M12 socket
sensor supply L+
sensor supply L-
data input I
data input II
not used
Data bit
Inputs / outputs
D0
D1
D2
I-1
I-2
O-3
I-1/PIN
I-2/PIN
1
1
3
3
4
2
4
5
2+5
D3
9