Herunterladen Diese Seite drucken

EINHELL GE-CL 18 Li Kit B Originalbetriebsanleitung Seite 17

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
11. Charger indicator
Indicator status
Green is fl ashing
Red is on
Green is on
Red is fl ashing
Red and green are fl ashing
alternately
* For our latest prices and information please go to www.isc-gmbh.info
Anl_GE_CL_18_Li_Kit_B_SPK7.indb 17
Anl_GE_CL_18_Li_Kit_B_SPK7.indb 17
GB
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Charging
The charger is charging the battery pack.
The battery is charged and ready for use.
(Charging time for 1.5 Ah battery: approx. 2 hours)
(Charging time for 2.0 Ah battery: approx. 2.5 hours)
(Charging time for 3.0 Ah battery: approx. 4 hours)
(Charging time for 4.0 Ah battery: approx. 5 hours)
(Charging time for 5.2 Ah battery: approx. 6.5 hours)
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Fault
Charging is no longer possible. The battery pack or charger is defec-
tive.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20°
C) for one day .
Should this fault still occur afterwards, the battery has undergone ex-
haustive discharge and must never be charged or used again. Take the
battery pack out of the charger.
- 17 -
14.03.2017 14:07:29
14.03.2017 14:07:29

Werbung

loading

Diese Anleitung auch für:

34.335.20