Troubleshooting
Online Support
http://www.bosch-indego.com
Problem
Possible Cause
The LED on docking
The perimeter wire is broken, too long or too
station flashes
short. Wire not connected and mower not in
the docking station
Excessive vibrations/
Blade nut/bolt loose
noise
Cutting blade damaged
Machine not docking
Perimeter wire not properly setup around
reliably
dock
Perimeter wire close to a source of interfer-
ence
Machine fails to oper-
Isolator switch not turned on
ate
Possible clogging
Battery not fully charged
Grass too long
Battery too hot/cold
Perimeter wire close to a source of interfer-
ence
Machine does not
Battery too hot/cold
charge
Docking station not switched on
Bosch Power Tools
Corrective Action
Check perimeter wire is not broken and is between 20
and 250 meters in length. Then switch off and on power
supply.
Follow instructions in Installation guide to install the
mower.
Tighten blade nut/bolt to torque of 2.5 Nm
Replace the blade
Follow instructions in installation guide to align wire
Leave adequate distance between your perimeter wire
and source of interference (approx. 1 m)
Change perimeter wire ID in the menu
Remove mower out of the dock, turn on switch and re-
place mower back in the dock (ensure dock is on – LED
is solid green). Press confirm button for screen to light
up. Enter 4 digit PIN to activate your mower
Always turn isolator switch off first, then check under-
neath the mower and clear out as necessary (always
wear protective gloves)
Replace mower in the docking station to charge. Docking
station must be on.
Mow garden to at least 40mm before using Indego.
Increase height of cut
Allow mower to cool/warm or move dock to area of
shade. Mower runs when battery internal temperature is
between 5°C – 45°C
Leave adequate distance between your perimeter wire
and source of interference (approx. 1 m)
Change perimeter wire ID in the menu
Allow mower to cool/warm or move dock to area of
shade. Mower runs when battery internal temperature is
between 5°C – 45°C
Switch on power supply to docking station or contact
your Bosch service centre
F 016 L81 221 | (2.12.16)