1 Basic Information
1.1 Notes for the User Manual
This user manual describes the structure of the KLEIBER 740 infrared pyrometer for non-contact temper-
ature measurement and gives the operators all the necessary information related to installation, operation,
de-installation along with information related to maintenance and repairs of the pyrometer. When malfunctions
occur, the user manual provides suggestions for their potential causes and their repair.
This user manual is intended for qualified service and maintenance personnel with appropriate technical ex-
pertise including a basic knowledge of temperature measuring technology.
Before you use the pyrometer for temperature measurement, you must have read and understood these oper-
ating instructions! Keep the manual so that it is available at all times.
Take into account all the requirements given in this user manual. This is a precondition for:
• The correct and professional use of the pyrometer
• Proper maintenance, cleaning and care of the pyrometer
• Prevention of risks and strict observance of the essential technical safety regulations
1.2 Document Structure and Symbols
Operating instructions to be performed in sequence are numbered in chronological order. They are grouped
together in operational units and accompanied by the corresponding results.
Listings without a sequential order are presented as bullet points and items in sub-lists are preceded by
dashes.
Safety precautions are shown with pictograms and key words. They provide information about the type,
source and consequences of the hazard, and safety precautions. The meanings of the pictograms and key
words are explained in Safety (section 2) at page 3.
1.3 Purpose
The KLEIBER 740 pyrometer is particularly intended for the non-contact measurement of surface temperatures
on metal, ceramic, plastics and is specially designed for industrial applications as well as applications in the
area of research and development.
The KLEIBER 740 also enables you to solve high speed applications in laser areas by using laser rejection
filters and challenging temperature measurement on silicon or tungsten.
1.4 Intended Use
The KLEIBER 740 pyrometer is to be used exclusively for the non-contact measurement of surface tempera-
tures of the materials specified in Purpose (section 1.3) at page 1. Any applications beyond that area are not
allowed! Any damage resulting from this is the sole responsibility of the operator.
Proper use of the device also includes:
• The observance of the requirements of these operating instructions for transport and storage, assembly,
operation and care of the pyrometer
• The observance of the power requirements specified in Technical Data (section 4) at page 7 and the
operating and environmental conditions
• The compliance with the legal accident prevention and environmental regulations
Among applications/conditions for which the pyrometer is not intended for use are in particular:
• The use of the pyrometer within medical areas
KS / KG / KGA 740
1 Basic Information