Introduction
Thank you for purchasing this TANNOY Ceiling Monitor System product. This product range is suited for high-level music and speech reinforcement applications
requiring exceptional sonic quality with uncompromised reliability.
Unpacking
Every TANNOY product and accessory is carefully inspected before packing. After unpacking, please inspect your product to make sure no damage has occurred in
DDA
transit. In the unlikely event of any damage, would you please notify your dealer immediately and retain your shipping carton, as your dealer may ask you to return the
faulty unit to him for inspection.
Each CMS loudspeaker is packed in pairs and provided with the following accessories as standard; C Ring, tile-bridge kit, grille, cut-out template, and paint mask.
A plaster (mud) ring is also available as an optional extra.
Safety Notices
Some regional construction codes require the use of a secondary method of securing loudspeakers in ceiling to provide security of a back up support. A secondary
support line should be attached from the safety loop on the rear of the product to a source point on the ceiling. Please consult the relevant construction codes in
your region.
When using a power driver to install the product it is essential to use the correct torque level settings to avoid over tightening and damage to the ceiling
material or clamps. Recommended torque setting: 1.5Nm
TANNOY will not be held responsible for any damages caused by the improper installation of these loudspeakers.
Electrical Saftey Notice: To comply with the standard UL1480, metal - clad flexible conduit (BX) is required for connection to the terminal block for proper
earth grounding.
In order to comply with UL regulations, the PI back-can must always be used with the CMS PI models.
SAFETY NOTE:
In order to comply with relevant fi re safety regulations (i.e. BS 5839:1998), it is required that in the event of fi re, that failure of the circuit to which the loudspeaker is connected does not occur before evacuation of the building is complete. Suitable measures include:
- a) use of terminal blocks (for connection to primary) with a melting point of not less than 650°C, for example constructed from ceramic materials; c) use of terminal blocks of a lower melting point but protected with thermal insulation; d) use of terminal blocks such
that, on melting, an open-circuit or a short-circuit does not occur.