Herunterladen Diese Seite drucken

Oase Bitron Eco 120 W Bedienungsanleitung Seite 23

Vorschau ausblenden Andere Handbücher für Bitron Eco 120 W:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
ProfiClear Premium / ProfiClear Classic
This section describes the connection of the UVC clarifying unit Bitron with a pump fed system.
• Please adhere to the instructions for use of the flow-through filter.
• The bypass membrane is fitted on delivery and is located in the outlet opposite the inlet.
• OASE recommends closing the bypass in the following situations:
– Acute problems such as disease or turbidity due to a build-up of bacteria.
– Low flow rates:
Bitron Eco 120 W: < 10000 l/h
Bitron Eco 180 W: < 13000 l/h
Bitron Eco 240 W: < 15000 l/h
How to proceed:
 E, F
1. Insert the outlets with flat seals through the holes in the container wall.
2. Fitting the inlet:
– ProfiClear Premium: First screw the adapters onto the outlets and hand tighten. Then screw
the 30° inlet bends with the union nuts onto the adapters and hand tighten. Ensure that
the openings point downward.
– ProfiClear Classic: Screw the inlet nozzles with the O rings onto the outlets and hand
tighten.
3. Closing the bypass (optional):
– ProfiClear Premium: Screw the cover cap onto the outlet instead of the adapter and inlet
bend.
– ProfiClear Classic: Screw the cover cap onto the outlet instead of the inlet nozzle.
4. Connect the Bitron to the filter pump. (→ Connecting the inlet)
BioTec ScreenMatic
• Please adhere to the instructions for use of the flow-through filter.
With bypass
• The bypass membrane is fitted on delivery and is located in the outlet opposite the inlet.
How to proceed:
 G
1. Insert the outlets with flat seals through the holes in the container wall into the distributor.
2. Screw the distributor nuts with O rings onto the outlets and hand tighten.
3. Connect the Bitron to the filter pump. (→ Connecting the inlet)