Automatic mode ProMax ClearDrain 7000
When the water level rises, it lifts the float switch until the switch-on point is reached and the
pump switches on.
When the water level drops, the float switch lowers until the switch-off point is reached and the
pump switches off.
 Push the float switch cable into the cable clip.
– The shorter the cable between the float switch and the cable clip, the lower the switch-on
point and the higher the switch-off point.
To ensure fault-free function, ensure that the cable length between the float switch and the
cable bracket is at least 100 mm.
The minimum residual water height is only reached in manual mode.