Quickguide | eBOX - Modbus Energiemanagement
4.
Register Spezifizierung
4.1.
Modbus Register Specification
Chargebox ID
Serial Number
Active Protocol
Manufacturer
Platform type
Product type
Modbus table version
Firmware version
Number of sockets
OCPP state
Socket 1: Mode 3 state
Socket 1: Cable state
Actual max. current phase 1
applied, which is influenced by all
box conditions
Actual max. current phase 1
applied, which is influenced by all
box conditions
Actual max. current phase 1
applied, which is influenced by all
box conditions
Phase 1 current
Phase 2 current
Phase 3 current
Maximum phase 1 current
8
ChargeboxID
R
SerieralNumber
R
ActiveProtocol
R
Manufacturer
R
PlatformType
R
ProductType
R
ModbusTableVersion
R
FirmwareVersion
R
NumberOfSockets
R
OcppState
R
Socket1Mode3State
R
(States from IEC 61851-1 Ed3)
Socket1CableState
R
ActualMaxCurrentPhase1
R
ActualMaxCurrentPhase2
R
ActualMaxCurrentPhase3
R
CurrentPhase1
R
CurrentPhase2
R
CurrentPhase3
R
MaxCurrentPhase1
RW
0
25
STRING
-
25
25
STRING
-
50
25
STRING
-
100
25
STRING
-
125
25
STRING
-
150
25
STRING
-
175
1
UNSIGNED16
-
200
25
STRING
-
225
1
UNSIGNED16
-
250
1
UNSIGNED16
-
275
2
STRING
-
300
1
UNSIGNED16
-
1000
2
FLOAT32
[A]
1002
2
FLOAT32
[A]
1004
2
FLOAT32
[A]
1006
2
FLOAT32
[A]
1008
2
FLOAT32
[A]
1010
2
FLOAT32
[A]
1012
2
FLOAT32
[A]
-
eBOX6867
-
LE006867
-
homeBOX
-
CCT GmbH
-
n/a
-
n/a
-
5
-
1.3.26
0 - 9
1
-
0
A, B1, B2, C1,
C2
C2, D1, D2,
E, F
0 - no cable
3
1 - cable
without the
car
2 - unlocked
cable
without the
car
3 - locked
cable with
car
6 - 32
16
6 - 32
16
6 - 32
16
0 - 32
9.88
0 - 32
0
0 - 32
0
6 - 32
16

Werbung