Herunterladen Diese Seite drucken

Kärcher K 2.13 Bedienungsanleitung Seite 11

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Power switch
The appliance switch prevents unintentional op-
eration of the appliance.
Lock trigger gun
This lock locks the lever of the trigger gun and
prevents the inadvertent start of the appliance.
Overflow valve with pressure switch
The overflow valve prevents the permissible
working pressure from being exceeded.
If the lever on the trigger gun is released the
pressure switch turns off the pump, the high-
pressure jet is stopped. If the lever is pulled the
pump is turned on again.
Prerequisites for the appliance's
stability
Caution
Create stability for the appliance prior to all work
on or with the appliance to prevent accidents or
damage.
The stability of the appliance is warranted
when it is placed onto an even surface.
Operation
Description of the Appliance
The scope of delivery of your appliance is illus-
trated on the packaging. Check the contents of
the appliance for completeness when unpack-
ing.
In the event of missing accessories or any trans-
port damage, please contact your dealer.
Illustrations on Page 2
1
High pressure connection
2
Detergent suction hose (with filter)
3
Appliance switch "0/OFF"/ „I/ON"
4
Storage for mains connection cable
5
Carrying handle
6
Connection for water supply with filter
7
Coupling element for water connection
8
Mains cable with mains plug
9
Trigger gun
10 Lock trigger gun
11 High pressure hose
12 Clamp for high pressure hose
13 Spray lance with Dirtblaster
Special accessories
Special accessories expand the possibilities of
using your appliance. Please contact your
KÄRCHER dealer for further information.
Illustrations on Page 2
Illustration
Pull out the clamp for the high-pressure hose
from the trigger gun (e.g. a small screwdriver).
Illustration
Connect high pressure hose to trigger gun.
Push the clamp in until it locks. Check the se-
cure connection by pulling on the high-pres-
sure hose.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply with-
out a system separator. Use a suitable
system separator manufactured by KÄRCHER;
or, as an alternative, a system separator as per
EN 12729 Type BA. Water flowing through a sys-
tem separator is considered non-drinkable.
Note: Impurities in the water can damage the
high-pressure pump and accessories. For pro-
tection, the use of the KÄRCHER water filter (op-
tional accessory, order no. 4.730-059) is
recommended.
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/technical
data.
Use a fibre-reinforced water hose (not includ-
ed) with a standard coupling. (Minimum diam-
eter 1/2 inch (13 mm), minimum length 7.5 m).
Screw the coupling element (supplied) to the
water connection on the appliance.
Push the water supply hose onto the cou-
pling unit, then connect it to the water supply.
Caution
Dry runs lasting longer than two minutes lead to
damages to the high pressure pump. If the appli-
ance does not build up pressure within two min-
utes, switch it off and proceed as instructed in
the Chapter "Troubleshooting".
Connect the high pressure hose to the high
pressure connection of the appliance.
Push the spray lance into the trigger gun and
fasten it by turning it through 90°.
Completely open the water tap.
Insert the mains plug into the socket.
Turn on the appliance "I/ON".
– 5
EN
Before Startup
Water supply
Start up
11

Werbung

loading