❺ Troubleshooting
• If a problem occurs, before you contact your retailer, please carry out these few simple checks
using the following tables.
• If the problem persists, contact your retailer.
: Actions to be performed by a qualified technician only
5.1 I Appliance behaviour
When the cleaner moves forward in
a straight line, it is no longer flat on
the floor.
(To run on the pool floor, it is normal
for the front of the cleaner to rise)
The cleaner does not or no longer
climbs the pool sides as it originally
did.
(Its electronic programme
means that the cleaner does not
systematically climb the walls).
The cleaner does not move on
start-up.
The cable gets tangled
The cleaner doesn't clean the entire
pool
The cleaner's discharge nozzles
become blocked
The control box does not respond
to any button presses.
The robot does not tilt upwards to
climb the walls
The cleaner climbs the walls slowly
and stops under the water line
The cleaner climbs the walls
quickly and goes past the water
line, aspirating air
• There is still air in the appliance's casing. Repeat the cleaner immersion
operations (see § "3.3 I Immersing the cleaner").
• The filter is full or dirty: simply clean it.
• The propeller is damaged, contact your retailer
• The filter is full or dirty: simply clean it.
• The filter is clogged: clean it with an acidic solution (spirit vinegar, for example),
or replace it where necessary.
• Even though the water seems clear, microscopic algae are present in your
pool, they are not visible to the naked eye, and they make the sides slippery
and prevent the cleaner from climbing. Carry out shock chlorination and slightly
reduce the pH. Do not leave the cleaner in the water during shock treatment.
If the problem continues contact your retailer
• Check that the outlet to which the control box is connected is receiving a
power supply.
• Check that the cleaning cycle has been launched and that the light is on.
If the problem continues contact your retailer
• Check that you place as much of the floating cable as possible in the water.
• Stop the filter pump and begin a new cleaning cycle.
• Place the control box halfway along the length of the pool, in accordance with
the safety conditions, see "3.4 I Electricity supply connections". If cleaning is not
optimal, vary the location of the control box and the place at which the cleaner
enters the pool.
• Unplug the cable from the mains socket, wait 10 seconds and plug it back in
again.
• The brush is worn: check the wear indicators "4.4 I Replacing the brush"
and that the brush is properly attached to its brush support. Replace the brush
where necessary.
• The pool is tiled with a right angle between the floor and the walls: the brush
may require adaptation to optimise cleaning: contact your retailer
• The cleaner may behave differently depending on the lining of the pool. A
parameter may require changing. To do this, contact your retailer