Connection to the mains

The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1
Connect the device via the enclosed mains cable to a grounded mains socket. Thus the unit is switched
on.
2
To switch off the unit, disconnect the power plug.
3
Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains
outlet which is switchable.

Stand-alone operation

In stand-alone mode, the LED TMH-S60 can be used without controller. Disconnect the LED TMH-S60 from
the controller and call up the internal program. Please refer to the instructions under Menu structure.

Master/Slave operation

The master/slave operation enables that several devices can be synchronized and controlled by one master
device.
On the rear panel of the device you can find an XLR-jack (DMX Out) and an XLR-plug (DMX In), which can
be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave-devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT-jack with the DMX IN-plug of the next device.
Define the master device with the MAST setting then set the desired master mode "Auto" or "Soun". Set the
desired slave mode "SL 1" or "SL 2" on all slave devices. Please refer to the instructions under Menu
structure.

OPERATION

After connecting the device to the mains it is ready for operation. The display indicates the last operating
mode. The operating modes can be selected by means of the display and the control buttons. All settings
remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone
mode via the control board or in DMX-controlled mode via any commercial DMX controller.
After you connected the effect to the mains, the EUROLITE LED TMH-S60 Moving-Head Spot starts running.
During the Reset, the motors are trimmed and the device is ready for use afterwards.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.

Menu structure

The main menu is accessed by pressing Menu until the display is lit. Browse through the menu by pressing
Menu. Press Enter in order to select the desired menu. You can change the selection by pressing Up or
Down. Press Enter in order to confirm. You can leave every mode by pressing Menu. The functions
provided are described in the following sections.
Depending upon the setting in the control board, the display shuts off after 10 seconds of inactivity. By
pressing any button it lights up again.
23/28