Herunterladen Inhalt Inhalt Diese Seite drucken

Problems And Solutions - Frank bSteam bS108 VAC Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Problems and solutions

Error
Steam leaks from the accessories
Steam sealing cap is difficult to insert
into the outlet of the machine
The boiler needs more time to heat up.
The pressure drops quickly when
steam is used
Intervention of the circuit breaker
during use. (Probable dispersion from
resistor or electric valve to ground).
Vacuum does not work (motor does not
start). (probable intervention with
interruption of the fuse to protect the
socket, for excessive absorption or
failure of the motor).
Steam escapes from the outlet valve in
the bottom of the machine.
This is due to wear or damage of
O-rings. Replace them, being careful not to damage
them, and insert them carefully.
Do not apply force when inserting and instead apply a
little silicone lubricant to the
O-rings and into the connector.
Clean the boiler as described. If necessary, carry out
the absorption with the capacity specified in the
technical data test.
This is due to the limestone, clean the boiler as
described.
(qualified personnel)
Make sure that the power cord is not visibly damaged.
Try plugging it into a different outlet. Make sure there
are no spills or water leaks from the machine. In this
case, it must be checked at a qualified dealer.
(qualified personnel)
After checking the power interruption in the vacuum
suction with the vacuum control activated, disconnect
the power plug, open the machine and replace the
fuse (8A 250V timed). Before reconnecting it, check
that the motor is not short-circuited or has electrical
problems.
(qualified personnel)
Check the correct working pressure of the boiler,
check the operation of the level probe and replace the
safety valve with an original spare part with identical
characteristics.
16
Solution

Werbung

Inhaltsverzeichnis
loading