6 Configuration
INFORMATION
During the first connection, the app (Daikin User or Daikin
Installer) synchronises with the controller software via a
cloud connection. This means that an internet connection
is required, at least for this first connection. If not, the
required packet can also be retrieved from the cloud as
soon as the connection is restored (via the "Packet
Manager" section of the app).
6.2

To unlock the user interface

To unlock the user interface
1 Press any button.
Result: The display shows the message "Loc".
2 Press the PROGRAM button for three seconds to exit lock
mode.
Result: The display shows three dashes in sequence.
Installation manual
18
3 s
6.3

To change the parameters

1 Unlock the user interface. See "6.2  To unlock the user
interface" [ 4  18].
2 Press the PROGRAM button to enter "dir" mode.
Result: The display shows "dir".
3 Use the UP (a) and DOWN (b) buttons to navigate towards the
desired menu, then press the PROGRAM (c) button to enter the
menu.
a
UP button
b
DOWN button
c
PROGRAM button
CtL
Control menu
Pro
Display probes menu
HcP
HACCP menu
CnF
Configuration menu
ALM
Alarms menu
PSd
Service menu
ESC
Exit the menu loop
Note: To return to the standard display, go to "ESC" and press the
PROGRAM (c) button.
INFORMATION
If no button is pressed, the terminal will return to the
standard display after 7 seconds.
a b c
LMSEY1A09/13 + LMSEY2A19/25
Daikin LMS
4P728170-1B – 2023.07