robot.
 Do not expose the battery to fire or intense heat as this may result in an
explosion.
CAUTION!
If a battery leak occurs, avoid any contact with the leaking fluids and place the damaged
battery in a plastic bag.
-
If leaking fluids come in contact with skin and clothing, wash immediately with plenty
of soap and water.
-
If leaking fluids come in contact with eyes, do not rub eyes, immediately flush eyes
with cool running water for at least 15 minutes and do not rub them. Seek medical
attention as soon as possible.
How to remove the battery pack for battery disposal only (To be done by
authorized technician)
Recommended tools (not included): Screwdriver.

Follow section "EMPTYING THE DEBRIS COMPARTMENT" to release

1.
the top cover (preassembled with the swivel head). Place the cover upside
down and use the screwdriver to unfasten the screw on the bottom locking
plate. Turn the bottom locking plate anticlockwise to release the swivel head.
Remove the swivel smoothening-ring.
2. Use the screwdriver to unscrew the 4 screws located at the bottom of
the head to release the bottom plate first, then unscrew all the screws at the
base as shown. Remove the impeller and pry open the base to expose the
head inside.
3. Remove the battery pack to expose the PCBA. To detach the battery
connection wire, press on the clip of the connector to pull it out. NOTE: Wrap
the connector immediately with insulating tape in order to avoid any short
circuit caused by the contact of both wire terminals.