Herunterladen Inhalt Inhalt Diese Seite drucken

Oase BioTec ScreenMatic2 40000 Gebrauchsanleitung Seite 69

Vorschau ausblenden Andere Handbücher für BioTec ScreenMatic2 40000:
Inhaltsverzeichnis

Werbung

BioTec ScreenMatic
How to proceed:
 Remove the substrate tubes individually and clean them or replace their contents.
– BioTec ScreenMatic
Cleaning/replacing the ScreenMatic screen
Prerequisite:
 The filter pump is switched off.
 The container is open. (→ Remove the container cover)
 The debris tray is removed. (→ Hinging the screen holder up/down)
How to proceed:
1. Remove the screw for fastening the control device, remove the control device and place it
carefully to the side.
– If necessary, disconnect the motor cable plug from the control device.
– Mark the position of the control device on a side section for reassembly.
2. Take the ScreenMatic rotating screen unit out of the screen holder.
– Biotec ScreenMatic
the ScreenMatic rotating screen unit.
– Biotec ScreenMatic
the water distributor and remove.
3. Undo the nuts on the side section, and remove the side section and stripper.
4. Release the clamping lever and remove the ScreenMatic screen.
– Thoroughly clean the stripper.
– Thoroughly clean both sides of the ScreenMatic screen. Replace the ScreenMatic screen if
necessary.
– Use the pump cleaning agent PumpClean from OASE.
5. Reassemble the ScreenMatic rotating screen unit in the reverse order and place it into the
screen holder.
– When tensioning the ScreenMatic screen, ensure that the clamping lever engages.
145000
2
145000: Twelve substrate tubes
2
40000, 60000, 90000: Press the locking clips on both sides and remove
2
145000: Press the ScreenMatic rotating screen unit in the direction of
2
EN
BTC0080
69