Herunterladen Inhalt Inhalt Diese Seite drucken

Observations; Warranty Conditions; Disposal; Troubleshooting - Sagola 612 Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 51
30/31

14. Observations

By following the instructions set out in this manual you will ensure good spraying and quality of
finish. Should you have any doubt, please contact the Technical Service of SAGOLA.

15. Warranty Conditions

This device has been manufactured with great precision and has been subjected to a large
number of controls before leaving the factory.
The WARRANTY is valid for 3 years, counted as of the date of purchase, which will be indicated by
the seller in the place provided for this purpose, together with his stamp. Once the unit has been
received, please complete the warranty and send this to the manufacturer for validation
This WARRANTY covers any manufacturing defect, which will be repaired without charge.
However, any malfunction resulting from the incorrect use of the unit, such as inadequate
connections, breakage due to dropping, or similar, the normal wear of components and in general
any deficiency not attributable to the manufacturer of the device, are expressly excluded. Likewise,
the WARRANTY shall be rendered null and void when it is evident that the unit has been handled
by persons other than our Technical Assistance Service.
This WARRANTY does not support any undertaking made by anyone outside our Technical
Service.
In the case of any breakdown during the guarantee period, deliver this to the nearest Technical
Assistance Service or get in touch with the factory.
Any demand of greater importance against the supplier, in particular compensation for damages,
is excluded. This is also applicable to any damages that might arise during counselling, while
acquiring practice and during demonstration.
Consequently, the services rendered under guarantee do not involve an extension of the warranty
period.
The manufacturer reserves the right to make technical modifications.

16. Disposal

For complete and correct disposal of the equipment, when it has reached the end
of its useful life, it must be completely dismantled so it can be recycled, separating
the metal and plastic components.

17. Troubleshooting

ANOMALY
The fluid does
Lack of air supply,
not come
or insufficient
out or
air supply
insufficient
output
NOTE: The symbol (*) means that before starting the procedure it is necessary to release pressure (see paragraph 9.1)
CAUSE
CHECK POINT
Twisted or obstructed
air hose and couplings
The two-way air inlet
valve is closed
Air leakage at the
air inlet
Air leakage from the
paint tank set
ENGLISH
REMEDY
Remove any restriction
to the air flow. (*)
Open the valve
Connect and tighten the
air hose properly
See troubleshooting
item 9

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis